10-20 KV 630 A-4000 A/25 KA-40 KA indoor metal-clad withdrawable switchgear
Number of views:
1010

10-20 KV 630 A-4000 A/25 KA-40 KA indoor metal-clad withdrawable switchgear

Retail price
0.0
Market price
0.0
Number of views:
1010
Contact:
Miss Sheng
TEL:
0513-85291811- turn to 670
E-mail:
2f920@nypc.com.cn
Product serial number
Quantity
-
+
Stock:
1
Product description
Parameters
产品说明
产品应用

Product picture

Product picture

Product description

Nanya has independently developed the metal-armored switchgear that complies with the standards IEC 62271-200 and GB3906.

Steel plates are applied for complete lockout and isolation.

High- and low-voltage units are thoroughly isolated.

The simple but effective interlock device is applied to prevent operating errors.

Cable connection can be inspected through the rear door.

The busbar is provided with the epoxy coating to strengthen insulation.

All unit chambers are separated from each other, in order to release pressure.

The busbar chamfer is optimized to prevent tip discharge.

Product certificate/Product catalog

KYN28A 12KV(Z)T1250A 40KA Inspection Report.PDF

KYN28A 12KV 1250A 40KA Inspection Report.PDF

KYN28A 12KV 1250A 31.5KA(Internal combustion arc) Inspection Report.PDF

KYN28A 12KV 1250A 31.5KA Inspection Report.PDF

KYN28A (F+C)7.2KV 200A 40KA Inspection Report.PDF

Product usage

Used in differeut fields such as power plants, substations, petrochemical enterprises, metallurgy, steel rolling, light industry, textile, factories, mining enterprises, residential communities, and high-rise buildings.

Product certificate/Product catalog

KYN28A 24KV T2500A 31.5KA Inspection Report.PDF

KYN28A 24KV 1250A 25KA Inspection Report.PDF

KYN28A 17.5KV 630A 31.5KA Inspection Report.PDF

KYN28A 12KV 4000A 40KA Inspection Report.PDF

KYN28A 12KV T3150A 40KA Inspection Report.PDF

KYN28A 12KV 2000A 40KA Inspection Report.PDF

Product description

Nanya has independently developed the metal-armored switchgear that complies with the standards IEC 62271-200 and GB3906.

Steel plates are applied for complete lockout and isolation.

High- and low-voltage units are thoroughly isolated.

The simple but effective interlock device is applied to prevent operating errors.

Cable connection can be inspected through the rear door.

The busbar is provided with the epoxy coating to strengthen insulation.

All unit chambers are separated from each other, in order to release pressure.

The busbar chamfer is optimized to prevent tip discharge.

Product usage

Used in differeut fields such as power plants, substations, petrochemical enterprises, metallurgy, steel rolling, light industry, textile, factories, mining enterprises, residential communities, and high-rise buildings.

Product certificate/Product catalog

KYN28A 24KV T2500A 31.5KA Inspection Report.PDF

KYN28A 24KV 1250A 25KA Inspection Report.PDF

KYN28A 17.5KV 630A 31.5KA Inspection Report.PDF

KYN28A 12KV 4000A 40KA Inspection Report.PDF

KYN28A 12KV T3150A 40KA Inspection Report.PDF

KYN28A 12KV 2000A 40KA Inspection Report.PDF

Product certificate/Product catalog

KYN28A 12KV(Z)T1250A 40KA Inspection Report.PDF

KYN28A 12KV 1250A 40KA Inspection Report.PDF

KYN28A 12KV 1250A 31.5KA(Internal combustion arc) Inspection Report.PDF

KYN28A 12KV 1250A 31.5KA Inspection Report.PDF

KYN28A (F+C)7.2KV 200A 40KA Inspection Report.PDF

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

NAN YA Electric (Nantong) Co.,Ltd.

Electric Machinery and Switchgear business office    Contact person: Miss Sheng
TEL: 86-513-85291811- turn to 670
E-mail: 2f920@nypc.com.cn

Copyrights © 2020 NAN YA Plastic (Nantong) Co., Ltd. 苏ICP备19024881号 Powered by 300.cn